The brake signal controls the activation of a Relay that triggers the sending of 24Vdc to release the brake. See the operation below to set the functions and DO wiring.
- Digital Output Setting (DO): Set the value for DO as 0x08 (BRKR). The configuration of parameters P1-42 and P1-43 is intended to control the release and activation time of the output (DO) according to the photo below.
- Refer to the wiring diagram below to use a DO output to actuate the electromagnetic brake.